Product Group
Doors, Fire Doors
System
AT 740 FR T30

System Description

With the AT 740 FR T30 fire door we were able to turn an established system into a construction to meet the highest standards. Effective fire and smoke control and attractive glass and frame construction do not conflict here. Apart from using the profiles from the base system and the respective accessories, eliminating coolant*¹ make a strong case for this system. It is very easy to install and hardly any different from a standard door. So you can easily implement fire doors with leaves about 1450 x 3000 mm in size.

Rendering

2D cross section

Product Specifications

Installation Depths

Frame 75 mm, leaf 75 mm, glazing bars 75 mm

Glazing

15 to 24 mm with fire protection glass*²

Panic function

as per DIN EN 179 / 1125

*¹ = coolant required in special cases *² = Pyrostop 30-10/12, Pyrostop 30-20, Promaglas “F1-30”

Leaf weight

max. 205 kg

Fire protection

as per DIN 4102-5

Smoke control

as per DIN 18095-1

Advantages
References
Downloads

Login to access secure downloads.

Teilen Sie diese Seite

Render-AT-740-FR-T30

AT 740 FR T30

Sie planen ein Projekt?
Lassen Sie uns sprechen!